![]() ![]() In the properties window, the serial number is now visible and can be adjusted if necessary. Now mark the peripheral tree the respective extension. Connect to your Miniserver and load out the PLC Config program. Once you have done this please contact our support.ĮXTENSIONS ARE NOT FOUND OR SOMETIMES GO OFFLINE?Ĭheck that the extension is connected to the correct serial number included in the program and stored in the mini server. If the resistance greatly increases at a certain point then you will have identified the extension causing the problem. If this minimum resistance is far from being met then connect the multimeter to ground and each terminal of each extension in turn. Depending on the total number of extensions the resistance will vary, see the table below on expected resistances.Ģ. Take a multimeter and measure the resistance between each of the two terminals and ground. If no errors were found in the resistance between the terminals of the blue connector continue to measure resistance.ġ. If the measured value is a lot different from these and you have checked the wiring and resistor please contact our support. Take a multimeter and measure the resistance between the two terminals of the blue connector. If the wiring has been checked and the reboot didn’t work check the resistance of the Link connectors with no power to the device. If this is not done damage can be done to the Loxone Link due to potential differences. ![]() If multiple power supplies are present, make sure that the grounds of all power supplies are connected. Check the quality of the wiring and the connections, if there is a loose connection or break in the wire of the Loxone Link this would cause this problem. Check that the last extension in the Link is terminated with the 120 Ohm resistor. Switch off the power supply and check that the Loxone Link blue connector is plugged in correctly. If there is still a problem go to step 2.Īdding the extension to the program did not solve the problem or is not showing up in the search so cannot add.ġ. Reboot the Miniserver and extensions (by turning the power supply off for about 10 seconds until rebooting). The green connector power plug should NOT be removed if the power supply is on.Ģ. Look in the periphery tree for the extension and check that the serial number is correct. The Miniserver does not see the extension connected because it has not been added to the program.Ĭonnect to your Miniserver and load the file from the Miniserver. #Loxone tree extension how to#If you have an extension with a status LED flashing orange and that won’t show up in the search in Loxone Config or is showing as offline look at the following table for tips on how to solve the problem: Reason When working with the equipment please do not work on it powered up! ONLINE TROUBLESHOOTING ![]() The blue Loxone Link connectors are especially sensitive to being plugged and unplugged if there is power to the devices. Damage to components can occur if this is not observed.īefore rebooting the extensions you should double check that all the connectors are plugged back in correctly and only then should you power up. ![]() Whenever work is done on the cabling of the Miniserver of any extensions please ensure that power to the installation is removed. ![]()
0 Comments
Leave a Reply. |
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |